Water supply and sewerage of 4-storey two-section house
- Added: 15.01.2015
- Size: 494 KB
- Downloads: 0
Description
I. Baseline data
1. The standard floor variant number is 4.
2. Quarter variant number -3.
3. The number of floors is 4.
4. The height of the floors is 3.0 m.
5. Absolute floor elevation of the first floor - 100.4 m.
6. The smallest guaranteed head in the city water supply is 26.0 m.
7. Absolute elevation of pipe tray in city sewage pit 8.7 m
8. The absolute elevation of the ground surface near the building is 13.0 m.
9. The penetration depth of negative temperatures is 0.80 m.
10. The absolute elevation of the pipe axis of the city water supply is 11.0 m.
11. The basement height is 2.2 m.
12. General Plan Data:
A) the distance from the building to the red line is 3.0 m.
C) the distance from the extreme building to the sewage well is 13.0 m.
13. The water consumption rate per person is 150 l/day.