Description

"Ventilation of a public building" 1. Calculation of heatreceipts, heatlosses, vlago- and gas-allocations to the settlement room of the building.............................................................4 2. Definition of the required air exchanges on different harmful allocations during the settlement periods of year and the choice of settlement air exchange in settlement room......................................................................8 3. The choice of settlement air exchange on the integrated indicators for other rooms of the building.........................................................11 4. Definition of number and location of incoming and exhaust ventustanovka.............................................................................13 5. Selection of basic solutions for ventilation air supply and removal for building premises. Solution of the issue of air duct material and placement of the latter in the building.................. 14 6. Sizing of ventilation ducts and screens........ 15 7. Aerodynamic calculation of ventilation systems........................... 17 8. Calculation and selection of the ventilating equipment - heaters, filters, fans and dr...........................................................25 9. Development of noise reduction measures, calculation of silencers.............................................................................................................................................................................................................................................................................................................

Project's Content

icon
icon
icon Ventilyatsia.doc
icon ventilyatsia2007.dwg

Additional information

Contents

General part

Calculation of heat inputs, heat losses, moisture and gas emissions to the design room of the building

Determination of required air exchanges for different harmful emissions in the calculated periods of the year and selection of the calculated air exchange in the calculated room

Selection of design air exchange by enlarged parameters for other rooms of the building

Determination of number and location of supply and exhaust ventilation units

Selection of basic solutions for ventilation air supply and removal for building premises. Resolve the issue of duct material and place the latter in the building

Sizing of ventilation ducts and grids

Aerodynamic calculation of ventilation systems

Calculation and selection of ventilation equipment - heaters, filters, fans, etc.

Development of noise reduction measures, calculation of silencers

Literature

Determination of number and location of supply and exhaust ventilation units

All rooms of the building are provided with a single plenum ventilation system. Since the club building does not have a basement, the plenum chamber is located on the first floor of the building. Air is supplied to the rooms using horizontal ducts. Rooms for accommodation of ventilation equipment are not recommended to be located directly behind the enclosing structures of the auditorium.

In the auditorium we design separate mechanical exhaust ventilation using a roof fan (B4). A separate mechanical exhaust ventilation system is provided from bathrooms, film projection, rewinding and radio unit (B2), while radial fans installed outside the building are used. Only channels from related rooms can be combined into one exhaust plant. Air from such rooms as storerooms, artistic, box office is removed by one exhaust ventilation system with a natural impulse (VE). When combining channels into exhaust plants, it should be taken into account that the range of the plant with natural traction is not more than 10 m, and with mechanical - not more than 30 m.

Selection of basic solutions for supply and removal of ventilation air for building premises. resolving the issue of duct material and placing the latter in the building

The layout of the network of air ducts is carried out using air ducts and shaped parts produced by LLC NIC "Master" in Minsk.

Air ducts of round section are placed along corridors (rooms No. 14, No. 10). They are in the set ceiling design.

Air is released through the shafts. The outer walls of the exhaust shafts are insulated to avoid condensation of water vapors from the removed air. Ducts are also insulated during external gasket. To protect against rain, snow, debris, an umbrella is installed above the mechanical exhaust ventilation shaft. Exhaust shafts are withdrawn 0.5 m above the flat roof.