• RU
  • icon Waiting For Moderation: 21
Menu

Reconstruction project of the building for multifunctional AR and NPP

  • Added: 14.08.2014
  • Size: 3 MB
  • Downloads: 0
Find out how to download this material

Description

The existing special transport building is a rectangular structure in plan, consisting of several buildings built at different times.

Project's Content

icon
icon
icon
icon 0111 АВАБИ Троллейбусная 10.dwg
icon Выдержки из норм по Троллейбусной.docx
icon Задание на проект на подпись последнее.rtf
icon Письмо про ширину здания.doc
icon План отдел1 письмо.dwg
icon Приложения.doc
icon Расчёты.docx
icon Съемка АВАБИ Троллейбусная 10.dwg
icon Съемка для письма.dwg
icon Съемка ориг АВАБИ Троллейбусная 10.dwg
icon Техзаключение1.doc
icon Тролейбусная 10. Магазин.. для Игоря..dwg

Additional information

Contents

CONTENTS

1. GENERAL PROVISIONS

2. BASIC PASSPORT DATA

3. GENERAL PLAN. LANDSCAPING AND LANDSCAPING

4. ARCHITECTURAL PART

5. CONSTRUCTION PART

6. SANITARY AND TECHNICAL PART

7. ELECTRICAL PART

8. PHYSICAL WEAR COUNT OF BUILDING

9. OWNER APPROVAL

Excerpts from Trolleybus standards:

Tkp 92 Fire propagation restriction

5.1.1 Rooms (groups of rooms) of different functional purpose, located in the same building, shall be allocated with fire barriers in accordance with the requirements of this technical code.

5.1.3 Degree of fire resistance of inserts, insertions, extensions and the built-on part of the building, except for specially stipulated cases, has to correspond degrees of fire resistance of the main building or the specified parts of the building have to be allocated with fire-prevention walls of 1 type.

5.1.4 At crossing of engineering communications of building structures with regulated fire characteristics, gaps between them for the entire thickness of structures should be filled with materials (articles) that do not reduce fire resistance and fire hazard class of the structure. (to mark in protivopozh. events).

5.1.15 Fire-fighting walls shall be supported by foundations or foundation beams, shall be erected to the entire height of the building, shall cross all structures and floors. Fire walls of type 1 may not cross fire floors of type 1, and fire walls of type 2 may not cross fire floors of type 3.

Fire walls can be installed directly on the structure of the building frame, structures or attached to them if they meet the requirements for these fire walls of the NSS 2.02.01.

Fire resistance limits of fire walls and floors shall comply with the requirements of NSS 2.02.01 in case of one-sided collapse of adjacent structures.

5.1.16 The height of the fire wall rise above the roof shall be taken, m, not less than:

0.6 - if at least one of the elements of the attic or attic-free coating, with the exception of the roof, is made of materials of groups G3, G4;

0.3 - if elements of attic or attic-free coating, with the exception of roof, are made of materials of groups G1, G2.

When using building structures with fire hazard class K0 (except roof) in the covers of buildings, it is allowed not to remove fire walls above the roof level.

5.1.18 In buildings with an internal angle, the horizontal distance from the nearest faces of the openings located in the external walls of rooms of categories A, B, B1VZ, administrative and residential premises to the openings of staircases, vestibules, rooms with a mass stay of people from the inner corner should be at least 4 m. If the distance between these openings is less than 4 m, they should be filled with fire doors (windows, hatches) of 2 types in buildings of II-IV degrees of fire resistance, 3 types - in buildings of V-VII degrees of fire resistance in one of the walls forming the internal angle.

5.1.21 … Fire doors and gates in fire barriers shall have seals in the receptacles and devices for self-closing. (to mark in protivopozh. events).

5.1.27 Enclosing structures of channels and shafts for laying utilities (with the exception of water supply, sewerage, steam and water heating pipelines made of their incombustible materials) shall have a fire resistance limit in buildings I-V of fire resistance not lower than REI 45 (for load-bearing structures) and EI 45 (for enclosing structures), fire hazard class K0; in buildings of VI and VII degrees of fire resistance - not lower than REI 15, EI 15 and K1, respectively.

Note - Doors and manholes of shafts for laying utilities shall have fire resistance limit not lower than EI 30 (in buildings of I-V fire resistance) and EI 15 (in buildings of VI and VII fire resistance).

When polymer pipes are used in water supply, sewerage, steam and water heating systems, it is allowed to protect only points of intersection of enclosing structures with such pipelines in accordance with 5.1.4.

5.1.32 In buildings with attics (except for buildings of VII and VIII degrees of fire resistance) at the device of rafters and furrings from combustible materials the waterproofing layer of a roof should be made of materials of groups of combustibility not below G1, distribution of a flame - not below RP1. (to mark in protivopozh. events).

5.1.32a In IVI buildings, the degree of fire resistance of the roof must correspond to the class BROOF (t1), BROOF (t2), BROOF (t3). In buildings of VII and VIII degrees of fire resistance, the roof should be of a class not lower than CROOF (t3).

5.1.41 To protect against atmospheric precipitation of sports stands and amphitheaters, the space between trade kiosks (pavilions) located outside buildings and structures, it is allowed to arrange visors from materials of flammability groups not lower than G2 and flame propagation - not lower than RP2 (class not lower than CROOF (t3), and entrances to buildings DROOF (5B) as per ST. At the same time, bearing elements of canopies (visors) must be made of non-combustible materials.

Fire resistance limits of bearing and enclosing structures of ramps and canopies are not normalized.

Fire resistance limits of bearing and enclosing structures of ramps and canopies are not normalized. Bearing and enclosing structures of ramps and canopies adjacent to IVI buildings of fire resistance, as well as separate canopies with an area of ​ ​ more than 2000 m2 should be taken from non-combustible materials.

5.6.1 When located in one building or room of technological processes with different explosion and fire hazard, measures to prevent explosion and spread of fire should be provided. The effectiveness of these measures should be justified in the process part of the project. If these measures are not sufficiently effective, then technological processes with different explosion and fire hazards should be placed in separate rooms; at the same time rooms of categories A, B and B1 - B3 should be separated from each other, as well as from rooms of other categories and corridors with fire partitions and fire floors of the following types:

- in IVVI buildings of fire resistance, buildings and structures with unprotected metal frame and enclosing structures made of steel profiled sheets or other non-combustible sheet materials with insulation of flammability groups not lower than G2 - fire partitions of type 1 and floors (intermediate and above the basement floor) of type 3 with fire hazard class K0;

When placing processes in a room with the same explosion and fire hazard, the need to separate them from each other with partitions should be justified in the technological part of the design, while the use of fire partitions is not mandatory, except in cases provided for by technological requirements.

5.6.7 Additions for accommodation of administrative and domestic premises shall be separated from production buildings of I-V fire resistance by fire partitions of type 1.

5.6.8 … Inserts in I-V buildings of fire resistance degree should be separated from production rooms by fire partitions of type 1. Buildings should be accepted with a number of floors of not more than two and separated from the industrial premises by fire partitions of type 1 and fire floors of type 3.

SNB 2.02.02 Evacuation

3.2 Exits are evacuation, if they lead from premises:

a) first floor outside directly, through a corridor, a lobby (foyer), a corridor and a lobby, a corridor and a staircase;

b) of any above ground floor - directly to the staircase of type 3, directly to the staircase or to the corridor (hall) leading to the staircase or to the staircase of type 3; the staircases shall have an exit directly to the outside or through the lobby separated from adjacent corridors by partitions with smoke-proof doors;

d) into an adjacent room on the same floor, provided with exits specified in subparagraphs "a," "b" and "c," with the exception of specially specified cases.

Evacuation exits to the outside can be provided through thermal vestibules.

Note - Stairs of type 3 can be used as only the second escape exits from the second and higher floors of buildings.

3.5 Parts of the building of various functional fire hazard separated by fire walls and floors of type 1 (fire compartments) shall be provided with independent escape routes.

3.9 From the building, from each floor and from the room, the internal tier of the storey (site),... At least two evacuation exits should be provided, with the exception of specially specified cases.

It is allowed to provide one evacuation exit (door):

a) from a room with an area of not more than 300 m2 (including a group of rooms with a total area of not more than 300 m2, excluding the area of ​ ​ general evacuation routes) located in the basement (basement) floor, if the number of permanently located in it does not exceed 5 people; with the number of people from 6 to 15, it is allowed to provide a second exit through a hatch with dimensions of at least 0.6x0.8 m with a vertical staircase or through a window with dimensions of at least 0.75x1.5 m with an exit device, more than 15 people. At least two evacuation exits shall be provided in accordance with requirements 3.2 of these regulations;

b) from a room located on any floor with a simultaneous stay in it of not more than 50 people, if the distance from the farthest point of the floor of the room along the escape routes to the specified exit does not exceed 25 m.

c) from a single-storey building or isolated (by fire barriers with a rated fire resistance of at least REI (EI) 45) part of the first floor of a multi-storey building with an area of ​ ​ not more than 300 m2 (except for rooms of categories A and B) with a simultaneous stay of not more than 15 people;

d) from any floor (except the first) or isolated (by fire barriers with a rated fire resistance rating of at least REI (EI) 45) part of the building with a height of not more than 15 m and an area of ​ ​ not more than 200 m2 with a simultaneous stay on each floor of not more than 10 people.

Note - Between isolated parts of buildings it is allowed to arrange openings while ensuring their protection against fire spread in accordance with the requirements of technical regulatory legal acts (hereinafter - TNPA).

3.13 Doors on escape routes shall open in the direction of exit from the building.

It is allowed to provide door opening inside:

when entering the air zone (except for doors leading to the outer air zone of staircases of type H1);

when entering ladder platforms of type 3;

from premises with simultaneous stay of not more than 15 people. (except for rooms of categories A and B, as well as steam saunas);

from pantries with an area of ​ ​ not more than 200 m2 and rooms of sanitary units.

3.16 The width of the outer doors of the staircases and doors when entering the lobby shall be not less than the calculated width of the flight of the staircase.

Staircase doors in the open position shall not reduce the normalized minimum width of staircases and marches.

For doors that open from spaces to shared corridors, the escape width of the corridor should be a reduced width in light:

half the width of the door canvas with one-sided door arrangement;

the width of the door canvas with double-sided door placement.

3.17 The width of the flight of the stairs shall be not less than the minimum width of the escape exit (door) from the most populated floor to the stairwell, but not less than 1 m, with the exception of specially specified cases.

The width of the staircases must be at least the width of the march...

3.19 Width of tambours (except for thermal tambours) and lock tambours shall be taken to be more than width of openings by not less than 0.5 m (0.25 m on each side of the opening), and depth - to be more than width of wide door or portal canvas by 0.2 m, but not less than 1.2 m.

3.20 Floor coverings in corridors, halls, lobby, staircases, as well as at the entrance to the building (porch, thermal vestibules, vestibules) shall be provided from materials with friction coefficient 0.40 < μ< 0.74 according to STB 1751. (to mark in protivopozh. events).

3.21 In the floor on the escape routes, height differences of less than 0.45 m and protrusions are not allowed, with the exception of thresholds in doorways with a height of not more than 0.06 m (when leaving rooms with a mass stay of people, the height of thresholds should not exceed 0.02 m). Stairs with a number of steps of at least three or ramps should be provided in places of height drop, at the same time these steps (ramps) should differ in color and contrast from other floor covering structures, with the exception of specially specified cases.

Ramp slope should be taken according to Table 1.

In case of gallery or rack height drop, a ramp with a slope of not more than 12 or a ladder with a slope of not more than 1:1 shall be provided in the passage. The distance from the beginning or end of the ramp or staircase to the door must be at least 1.5 m .

3.31 External evacuation doors of buildings (including doors of exits to stairs of type 3) shall not have locks, which cannot be opened from the inside without a key in case of fire.

In cases of necessity of locking devices on doors under the conditions of safety of valuables, the device of electromagnetic circuit breakers actuated manually, remotely and automatically (from fire automation units) is allowed. (to mark in protivopozh. events).

3.34 Stairs of type 3 used as the second escape exit shall be made of non-combustible materials and shall communicate with rooms through platforms or balconies arranged at the level of evacuation exits.

these stairs should normally be placed at the blind portions of the exterior walls. It is allowed to place these stairs against glazed openings with a spacer of at least 1 m, at the same time from the side of glazing the stairs should have a continuous fence 1.2 m high from incombustible materials, and exits from the floors to the stairs should be located outside the fence.

3.41 In IVII buildings of fire resistance on escape routes it is not allowed to use materials with higher fire hazard than:

G1, B1, D1, T1 for finishing walls, ceilings and filling suspended ceilings in vestibules, staircases and elevator halls;

G2, B2, D2, T2 for finishing walls, ceilings and filling suspended ceilings in common corridors, halls and foyer;

B2, PP2, D2, T2 for floor coverings (including carpets) in common corridors, halls and foyer;

NG for floor covering in vestibules, staircases, elevator halls

Frames of suspended ceilings in rooms and on escape routes should be made of non-combustible materials.

3.43 Walls and partitions enclosing common escape routes (corridors, lounges, lobbies and elevator halls) from adjacent rooms shall have a fire resistance limit of at least REI (EI) 45 in IIV buildings of fire resistance, REI (EI) 30 in buildings of V and VI fire resistance degrees, REI (EI) 15

3.47 Minimum evacuation width of corridors, passageways, galleries, racks, exits and doors in buildings shall be determined as per Table 2.

3.48 Minimum evacuation width and maximum slope of internal ladder flights shall be taken as per Table 3.

3.51 The distance along the corridor from the door of the most remote room to the nearest evacuation exit (except for latrines, washrooms, showers, smoking and other maintenance rooms) directly outside or into the stairwell shall not exceed the values given in Table 4.

3.86 It is allowed to provide one evacuation exit:

a) from rooms with engineering equipment in the absence of permanent stay of people in them through rooms of categories A and B, if the total length of the evacuation route (taking into account the passage through the room of category A or B) does not exceed 25 m;

b) from any floor of IIV buildings of fire resistance category D with the number of above-ground floors not more than four, with the number of people working in the largest shift on each floor not more than five and the floor area not more than 300 m2;

c) from a room located on any floor (except for the basement or basement), if this exit leads to two evacuation exits from the floor, the distance from the most remote workplace to the exit from the room is not more than 25 m, and the number of workers in the largest shift does not exceed, people:

5 in category A or B premises;

15 in the room of category B1;

25 in the room of category B2;

35 in the room of category B3;

40 in the room of category B4;

45 in the room of category G1;

50 in a room of category G2 or D;

d) from a room (building) with an area of ​ ​ not more than 300 m2: category D, any tier of the internal floor or platform in a room of category D, a building of class F5.4, if the number of employees in the largest shift does not exceed 5 people. (for buildings of class F5.4 50 people), at the same time the distance from the most remote workplace to the evacuation exit should not exceed 25 m;

f) from rooms located on antresoles and inserts (installations) in IIV buildings of fire resistance, as well as on antresoles of one-story buildings of VII fire resistance category D and D to stairs of 2 or 3 types, if in these rooms the distance from the most distant point to exit the stairs does not exceed 25 m.

(2 - internal, located outside staircases, open;

3 - external open).

3.88 As a second exit from the second and higher floors of buildings (inner tier of a storey or site) with a height of not more than 26.5 m from the planning elevation of the ground to the floor elevation of the upper floor (tier), in addition to technical, it is allowed to provide for stairs of type 3, if the number of workers on each floor (except the first) in the most numerous shift does not exceed, people:...

3.89 In buildings of class F5.4 as the second evacuation exit from the floor, it is allowed to use the exit to the staircase of type 3, taking into account the requirements of Table 9.

3.92 Exits from built-in and attached boiler houses shall be provided directly to the outside....

3.93 In the premises of category B1 with an area of ​ ​ more than 800 m2, exits should be placed so that there are no dead end evacuation routes with a length of more than 25 m. For the premises of category B2, this area is allowed to increase to 1000 m2, and for categories B3 and B4 to 1100 m2.

3.100 From built-in rooms of class F5.4, which are located in buildings of class F5 on mezzanines and platforms, it is allowed to provide exits to production rooms by open stairs. The distance from the exits from the built-in rooms to the exits to the outside should be taken in accordance with the standards for industrial buildings, depending on the category of the room for explosion and fire hazard.

3.103 The distance from the most remote workplace to the nearest escape exit from the room directly outside or to the stairwell shall not exceed the values given in Table 10.

3.105 The width of the escape exit (door) from the corridor to the outside or to the stairwell should be taken according to Table 11, depending on the total number of people evacuating through this exit and the number of people per 1 m width of the exit (door).

3.106 Type L1 staircases shall be provided in Class F5.4 buildings, attachments, inserts and attachments, except where otherwise specified.

In IIV buildings of fire resistance with a number of floors of not more than three 50% of staircases, it is allowed to provide for type L2, at the same time the distance between the staircase routes should be not less than 1.5 m. In these buildings, the main staircases can be designed open to the entire height of the building, provided that the remaining (at least two) staircases are located in staircases of type L1. At the same time, the vestibules and floor halls in which open stairs are located should be separated from adjacent rooms and corridors by fire partitions of type 1.

(L1 - with natural illumination through glazed or open openings in the outer walls;

L2 - with natural illumination through glazed or open openings in the coating).

3.114 The width of the escape exit (door) from the premises should be taken according to Table 12 depending on the total number of people evacuated through this exit and the number of people per 1 m width of the exit (door).

4.6 In the inner walls of staircases it is allowed to provide glazed doors and framugs above them, at the same time in buildings with a height of four floors and more, glazing should have a fire resistance limit of E 15.

In the light openings of the outer walls of the staircases, opening frames shall be provided with a total area of not less than 1.2 m2 on each floor...

4.7 Doors of staircases of all types leading to common corridors or separating them, doors of elevator halls and tamboursluises, doors of exits from the hall rooms with a capacity of more than 50 people, as well as doors of rooms with forced smoke ventilation should be designed as smoke-proof.

4.11 One of the internal stairs in IIV buildings of fire resistance not more than 26.5 m high (from the elevation of the roadway closest to the house to the floor mark of the upper floor, except technical) may be opened to the entire height of the building, provided that the room where it is located is separated from adjacent floor corridors and other rooms by type 1 fire partitions and type 2 floors.

4.20 In buildings of class F5.4 in corridors without natural light, intended for evacuation up to 50 people. and located in separate buildings and extensions with a height of not more than 10 floors and not less than 26.5 m from the average planning mark of the clean floor of the upper floor, as well as in inserts and installations with a number of floors of not more than two, it is allowed not to provide for a smoke removal system if:

a) corridors are intended for evacuation from administrative and domestic premises and do not communicate directly with storerooms and other rooms without natural light intended for storage and processing of combustible materials;

b) corridors are intended for evacuation from dressing rooms having natural lighting through windows in external walls.

TAP 22 Escape routes and exits

6.2.2 It is not recommended to arrange glazed partitions enclosing common escape routes and glazed doors in rooms with access to dead end corridors (Figure 6.9).

6.2.11 In buildings of F5 class, the requirements for the maximum permissible distance from the room door to the nearest evacuation exit set out in Table 4 of SNB 2.02.02 are determined from the room door having a more dangerous category according to [1].

6.3.1 For evacuation purposes it is allowed to use swing, sliding or lifting gates, if they are equipped with wickets that meet the requirements for evacuation exits (doors).

6.3.9 When designing, it is recommended to avoid large changes in the height of the floor, and in cases of inevitability of their arrangement, it is necessary to ensure a smooth transition of human flows when moving vertically. To do this, according to the requirement 3.21 of SNB 2.02.02, stairs with a number of stages of at least three or ramps are installed in places of height differences, since when the height difference is less than 0.45 m, it is impossible to ensure a safe smooth transition by arranging a minimum number of stages in the stairs.

6.4.8 Stairways shall not include less than three or more than 16 steps. In single-floor stairs, as well as in one march of two- and three-march stairs within the first floor, no more than 18 lifts are allowed...

6.5.3 It is not allowed to place exits from the unlit staircases in the inner corners of the external walls of the building (Figure 6.30)...

6.5.5 It is forbidden to make exits from storerooms and other rooms with combustible materials to unpumented staircases of all types, as well as to air zones of staircases of H1 type.

6.6.8 Passages shall ensure unhindered movement of people. Passages directly leading to evacuation exits are common.

The evacuation width of the common passages shall be not less than the width of the evacuation exits from the premises, but not less than 1 m. The width of the transport and pedestrian passages, determined by the requirements of the technology, is recommended to take at least the width of the open gates or doors. For evacuation no more than 50 people. it is allowed to take the evacuation width of the passage 0.9 m.

In F5 class buildings, passages are designed taking into account safety requirements, placement of workplaces and sizes of process equipment. The minimum evacuation width of the passages to single workplaces is allowed to be 0.7 m, which is sufficient for the movement of single-row flows.

6.6.12 The staircase doors shall be permanently in the closed position to ensure the non-smoke-free escape routes. For this purpose, TNPA provides for the installation on the doors of staircases leading to the common corridors and out, on the doors of elevator halls and tambourhalls, halls and vestibules intended for evacuation, devices for self-closing and sealing in the narrows.) . (to mark in protivopozh. events).

SNiP Fire safety standards

2.8. In buildings with a roof slope of up to 12% inclusive, a height from ground level to the cornice or the top of the outer wall (parapet) of more than 10 m, as well as in buildings with a roof slope of more than 12% height from ground level to the cornice of more than 7 m, fences on the roof should be provided in accordance with GOST 2577283. Regardless of the height of the fencing building, in accordance with the specified GOST, it should be provided for operated flat roofs, balconies, loggia, external galleries, open external stairs, staircases and platforms.

2.9. … For industrial and warehouse buildings, fire stairs shall be provided along the perimeter of the building not less than 200 m. It is allowed not to provide fire stairs on the main facade of the building, if the width of the building does not exceed 150 m, and on the side opposite to the main facade there is a line of fire water supply.

2.11. In places of roof height difference (including for lifting to the roof of light-air lights) more than 1 m, external fire stairs should be provided regardless of the height of the buildings.

2.13. To rise to a height of 10 to 20 m and in places of the height difference of roofs from 1 to 20 m, fire ladders of the 1st type should be used,... (1st - vertical steel with a width of 0.7 m, starting from a height of 2.5 m, with platforms when reaching the roof.)

TAP 90 Production buildings

The height of one-story buildings (from the floor to the bottom of horizontal load-bearing structures on the support) shall be at least 3 m, the height of the floor of multi-story buildings (from the floor of the staircase of this floor to the floor of the staircase of the overlying floor), with the exception of the height of technical floors, shall be at least 3.3 m.

If it is necessary to enter the car building, the height of the passage must be at least 4.2 m to the bottom of the structures, protruding parts of communications and equipment; for fire trucks - at least 4.5 m.

Galleries, platforms and ladders for maintenance of lifting cranes should be designed in accordance with the Rules for arrangement and safe operation of lifting cranes approved by the Department for Supervision of Safe Performance in Industry and Nuclear Power.

Smoke removal in case of fire shall be provided in rooms and corridors in accordance with the requirements of SNB 4.02.01.

Opening of window openings for smoke removal and ventilation shall be mechanized.

Automatic fire extinguishing and fire alarm shall be provided in accordance with the requirements of SNB 2.02.05 and [2].

SNB 4.02.01 Heating, ventilation and air conditioning

8.2 Smoke removal shall include:

a) from corridors or halls of residential, public, administrative and domestic buildings in accordance with the requirements of SNB 3.02.04, SNB 3.02.03 and SNiP 2.08.02;

b) from the corridors of industrial, administrative and domestic buildings with a height of more than 26.5 m (from the surface of the nearest passage for the fire engine to the floor level of the upper floor, not counting the upper technical floor);

c) from corridors more than 15 m long, which do not have natural illumination by light openings in external enclosing structures (hereinafter - without natural illumination), industrial buildings of categories A, B and B1 - B4 with a number of floors 2 and more;

d) from each production or storage room with permanent workplaces without natural lighting or with natural lighting, having no mechanized drives for opening the frames located at the level of 2.2 m and higher from the floor to the bottom of the frames, and for opening openings in the lights (in both cases, the area sufficient to remove smoke in case of fire), if the premises are classified as A, B and B1 - B4; G1, G2 or D - in buildings of VII, VIII degree of fire resistance;

e) from each room without natural light:

- public, administrative or domestic, if it is intended for the mass stay of people; Premises with an area of 55 m2 or more intended for the storage or use of combustible materials, if there are permanent workplaces; dressing rooms with an area of ​ ​ 200 m2 or more; trading rooms.

It is allowed to design smoke removal through the adjacent corridor from the production premises of categories B2 - B4 with an area of ​ ​ 200 m2 or less.

The requirements of this clause shall not apply to:

a) for premises whose filling time with smoke in accordance with 8.8 is longer than the time required for safe evacuation of people from the premises (except for rooms of categories A and B) in accordance with calculations as per GOST 12.1.004;

b) for premises with an area of less than 200 m2, equipped with automatic water and foam fire extinguishing units, except for rooms of categories A and B;

c) rooms equipped with automatic gas and aerosol fire extinguishing units;

d) laboratory rooms specified in Appendix U;

e) on corridors (halls), if direct smoke removal is designed for all rooms with doors to this corridor (hall).

If in the area of the main room for which smoke removal is provided, other rooms with an area of ​ ​ each 50 m2 or less are located, then separate smoke removal from these rooms may not be provided, provided that the smoke consumption is calculated taking into account the total area of ​ ​ these rooms.

TAP 209 Administrative and residential buildings

When designing buildings and premises, at least one entrance should be provided, designed for convenient access of physically weakened persons.

Before this entrance, a horizontal platform protected from atmospheric precipitation must be equipped with a plan size of at least 1.4 × 1.4 m. The height of the threshold for crossing from the site to the building should be no more than 2.5 cm.

To lift physically weakened persons to the level of the entrance to the building, the specified platform must be equipped with a staircase with a slope of not more than 1:3 and a ramp with a width of not less than 1.2 m.

The width of the tread of the stair step must be at least 36 cm, the height of the riser must be no more than 12 cm, and the radius of rounding from the tread to the riser must be no more than 5 cm. The steps of the stair must be of the same size, horizontal, blind and without protrusions.

Ramp slope shall comply with the requirements of SNB 2.02.02.

Steps along the sides of the stair flight not adjacent to the walls shall have sides with a height of at least 2 cm. Sides of the ramp and platform shall be provided with sides with a height of at least 5 cm.

Fences at a height of not less than 0.9 m with handrails at a height of 0.7 and 0.9 m should be arranged on both sides of the ramp and stairs, as well as on the sides of the platform that are not adjacent to the walls.

Handrails shall be at least 0.3 m longer than the ramp or ladder. Handrails shall have a thickness of not less than 3 and not more than 5 cm at the point where the hand is covered.

A platform not less than 1.5 m deep shall be provided in front of the staircase or ramp at the pavement level.

Entrance doors to buildings for physically weakened persons, including those moving on armchairs, shall have a width in the light of at least 0.9 m.

Tambours at entrances intended for physically weakened persons shall have dimensions in plan: with direct movement - depth not less than 1.8 m, width - not less than 2.2 m; when driving with a turn - at least 2.2 × 2.2 m.

Rooms for craftsmen and other personnel; rooms for rest, heating or cooling; latrines, washes, hand baths, half-chokes, drinking water supply devices

and personal hygiene of women is allowed to be provided in the built-in premises of industrial buildings, placing them dispersed and, as a rule, made of light enclosures, including prefabricated structures.

The height of the premises from floor to ceiling should be taken at least 2.5 m, in mobile buildings and rooms located directly in industrial buildings - at least 2.4 m. The height of the dining rooms, meetings and administrative rooms with a capacity of more than 75 people. take at least 3 m.

The floor elevation of the premises at the entrance to the building should be higher than the pavement elevation before the entrance by at least 0.15 m. When entering the buildings, devices for cleaning shoes should be installed.

On each floor of the building, storerooms of harvesting equipment should be provided, the area of which should be taken at the rate of 0.8 m2 for every 100 m2 of floor area, but not less than 4.0 m2.

If the floor area of the multi-storey building is less than 400 m2, it is allowed to provide one storeroom for two adjacent floors.

!!! Requires 1 shower, common cabinets.

5.2.3 … During the production processes of groups 1a, 1b, 2a, 2b and 3a, the dressing rooms should be common to all types of clothing.

During the production processes of groups 1b, 2b, 2g and 3b, separate dressing rooms for workwear for each of these groups should be provided. It is allowed to provide a common dressing room for workwear during the production processes of groups 1b, 2b, 2g and 3b with a list of all working groups up to 50 people.

Dressing rooms of street and dressing rooms of street and home clothing can be common to all groups of production processes.

5.2.7 In the case of common dressing rooms or dressing rooms for street and home clothing, storage rooms should be provided for clean and contaminated workwear, rooms for duty personnel with a place for cleaning equipment, places for cleaning shoes, ironing clothes, shaving, drying hair and manicure, as well as latrines for one or two floor bowls (toilet) if public latrines are not provided at a distance of up to 30 m from the exit from the dressing room.

5.2.8 Storage rooms for storage of workwear for production processes of groups 1 and 2a with the number of workers in the largest shift of up to 20 people. it is allowed not to provide.

5.2.14 Washrooms shall be placed adjacent to common dressing rooms or workwear. It is allowed to place washbasins directly in the specified dressing rooms on the areas provided for this purpose.

Up to 40% of the estimated number of washbasins can be placed near workplaces in production rooms, including in vestibules at latrines.

5.2.15 Latrines in multi-storey buildings shall be located on each floor.

If the number of workers on two adjacent floors is not more than 30 people. it is allowed to provide latrines only on the floor with the largest number of employees .

5.2.17 With the number of workers in the largest shift, no more than 15 people. it is allowed to provide a common restroom for men and women.

5.2.20 The entrance to the bathroom should be arranged through a tambour with a self-closing door .

5.2.26 The lower part of walls and partitions of workwear, shower, pre-shower, wash, latrine, rooms for drying, dusting and decontamination of workwear shall be made to a height of 2.0 m from the floor level from materials that allow for their easy cleaning and washing with hot water using detergents. The upper part of the walls and partitions - above the elevation of 2.0 m, as well as the ceilings of these rooms should have a water-resistant coating.

5.2.27. The distance to latrines, smoking rooms, rooms for heating or cooling, half-chokes, drinking water supply devices from workplaces in production buildings should be no more than 75 m (for persons with musculoskeletal disorders - no more than 60 m), and from workplaces on the site of the enterprise - no more than 150 m.

5.4.5 The area of the meal room should be determined at the rate of 1 m2 for each visitor or 1.65 m2 for a visitor using a chair, but not less than 12 m2.

The meal room shall be equipped with a washbasin, stationary reboiler, electric stove, microwave and refrigerator.

With the number of workers in the most numerous shift up to 10 people. instead of a meal room, it is allowed to provide a space of 6 m2 for the installation of a table in common dressing rooms or in dressing rooms of home (street and home) clothes.

6.1.1 The area of premises should be accepted at the rate of 4 m2 per one management employee and 6 m2 per one design bureau employee,...

Director General

We inform that the maximum possible dimensions in the axes of the designed production site on ul. Trolleybus 10 in the city of Gomel will be about 56x18 m (1008 m2). The area occupied by the existing production premises is about 40.8x12.5 m (510 m2).

For building construction in maximum dimensions it is necessary to perform:

- transfer of the water supply network ∅150 mm running parallel to the building with observance of the required distance from the foundations of the designed building;

- transfer of the water supply network ∅100 mm going between the existing building and TP115 falling under the building spot.

According to SNB 3.01.0402 "Urban planning. The layout and development of settlements "the distance from the foundations of buildings to the water supply networks should be at least 5 m. At the moment, the distance from the outline of the designed building to the water supply network ∅150 is about 4.38 m near the administrative part, and about 2.91 m near TP115. The length of the water pipeline ∅150 can be reduced to 60 m starting from the nearest well only when coordinated with the network owner. Please note that the distance to the well is taken from the outline of the building and is about 4.84 m. In reality, the distance from the foundations of the building protruding beyond the outline of the building will be less than the indicated within 1 m. Without coordination with the owner, the theoretical length of the network will be about 76 m.

When you decide to design the production area in the existing dimensions, we inform you that the distance to the water supply network of ∅100 mm coming between the existing building and TP115 is 3.21 m, which is less than 5 m and will also require the transfer of the network.

On the basis of the above, please provide a written response regarding the transfer of networks to determine the final dimensions of the designed building.

The diagram is attached .

With respect the director ,

General provisions

The basis for the inspection of the technical condition of structures and engineering equipment is: letter of order dated 22.12.2010, decision of the Gomel City Executive Committee No. 564 § 34 dated May 03 2010; No. 61 § 11 dated January 24, 2011

The purpose of the work is to determine the technical condition of structural elements and engineering equipment of the building for the preparation of design estimates.

Scope of work: study of technical documentation for the building, visual examination, analysis and synthesis of survey results, preparation of technical opinion.

Regulatory and methodological documents:

SNiP 2.01.0285. Fire safety standards. (paragraphs 2.1- 2.3, 2.7-2.11, 2.13)

SNiP 2.04.0284. Water supply. External networks and structures.

SNiP 2.04.0385. Sewerage. External networks and structures.

SNiP 2.04.0786. Heat networks.

SNiP 2.08.0289. Public buildings and structures

SNiP 3.05.0288. Gas supply.

SNB 1.04.0104. Buildings and structures. Basic requirements to the technical condition and maintenance of building structures and engineering systems, assessment of their suitability for operation.

SNB 1.04.0202. Repair, reconstruction and restoration of residential and public buildings and structures.

SNB 2.02.0201. Evacuation of people from buildings and structures in case of fire.

SNB 2.02.0403. Fire protection of settlements and territories of enterprises.

SNB 3.02.0403. Residential buildings.

SNB 3.02.0303. Administrative and household buildings.

SNB 3.03.0297. Streets and roads of cities, towns and rural settlements.

SNB 4.02.0103. Heating, ventilation and air conditioning.

SNB 4.03.0198. Gas supply.

TKP 452.02-22-2006. Buildings and structures. Escape routes and exits. Design Rules.

TKP 452.02-34-2006. Buildings and structures. Firefighters compartments. Design Standards.

TKP 451.04-37-2008. Survey of building structures of buildings and structures. Procedure for holding.

TKP 452.04-43-2006. Construction heat engineering.

TKP 454.01-52-2007. Internal water supply systems of buildings. Construction Design Codes.

TKP 454.01-54-2007. Internal sewerage systems of buildings. Construction Design Codes.

TKP 451.03-85-2007. Internal engineering systems of buildings and structures.

TKP 452.02-92-2007. Limitation of fire spread in buildings and structures. Space-planning and structural solutions. Construction Design Codes.

TKP 451.02-104-2008. Design documentation for the repair, modernization and reconstruction of residential and public buildings and structures. Procedure for development and approval .

TKP 453.01-116-2008. Urban planning. Settlements. Planning and development standards.

TKP 451.04-119-2008. Buildings and structures. Assessment of the degree of physical wear and tear.

TKP 451.04-126-2009. Survey of buildings and structures. Occupational safety rules.

TKP 452.02-138-2009. Fire-fighting water supply.

TKP 454.04-149-2009. Electrical systems of residential and public buildings. Design Rules.

GOST 30331. Electrical installations of buildings.

P1-2000 to SNB 4.03.0191. Design and construction of polyethylene pipes.

Allowance P82000 to SNB 5.01.0199. Design and arrangement of underground structures protection against groundwater.

"Rules of industrial safety in the field of gas supply to Belarus," 2009

Rules of technical operation of heat-using plants and heat networks of consumers and Rules of technical safety during operation of heat-using plants and heat networks of consumers, 2004.

Architectural part

Space Planning Solution

The existing special transport building is a rectangular structure in plan, consisting of several buildings built at different times.

The building is one-story, without a basement, with a volumetric and partially with a flat combined roof, and an unorganized external drainage.

The building consists of an administrative and household block, in which there are offices, bathrooms, ITP., An entry point, two car blocks-garages with a household, premises for rent, garage boxes for four cars, a warehouse. Car boxes have inspection pits.

The entrances to the building and to the garage boxes are carried out from the courtyard facade and from the courtyard territory of Tambur LLC at the entrance to the administrative block. The width of the corridors, taking into account the opening of the door blocks, is less than the standard one, according to paragraph 3.47 of SNB 2.02.0201.

Decoration of rooms on escape routes in administrative unit is made of combustible materials. which violates item 3.41 of SNB 2.02.0201.

The administrative block is separated from the garage block by a fire wall to the entire height.

Facades

The walls of the facades are made of ceramic brick and silicate stone. The walls are plastered and painted with facade acrylic paint. The walls of the late addition of silicate stone are not plastered.

The facades of the administrative block were repaired. The facades of the rest of the building have damage to the plaster layer and the paint layer.

Above the administrative block there is a new roof made of metal. The roof above the rest of the building is made of wavy asbestos cement sheets. Window blocks are wooden, glazing is partially absent. Window plums are broken. Window blocks in the administrative building are made new from PVC profile, new window drains and rolls are installed.

Interior decoration of rooms

The following decoration is made in the administrative block;

- cabins and corridor are glued with wallpaper for painting. The floors are ceramic, the ceilings are painted with acrylic paint.

Garage rooms are lined with ceramic tiles to a height of 1600mm. with acrylic paint, ceilings painted with acrylic paint, floors made of mosaic concrete.

In the rented room, a decorative panel made of PVC with oil color to the remaining height is made. Ceilings painted with acrylic paint, concrete floors.

Physical wear of interior trim 80%.

Window and door infills

Wooden window blocks with single glazing, painted. The paint layer has exfoliated, partially there is no glazing. The gate at the entrance to the boxes is metal, painted, in satisfactory condition.

Physical wear of wooden window blocks 80%

Physical wear of windows from PVC profile 10%

50% physical wear of metal gates

60% physical wear of door blocks

Conclusions and recommendations

When performing the reconstruction of this building for administrative trading, according to the customer's task, taking into account the current regulatory documents, it is necessary to perform the following;

-Reschedule ground floor spaces

-Perform the superstructure of the second floor, taking into account the load-bearing capacity of the structures.

-Swap window blocks.

- Repair the facades with subsequent painting.

- Perform decoration of the premises, according to the existing sanitary and fire regulations..

- Perform internal finishing of the administrative unit in accordance with SNB 2.02.0201.

Electrical part

Electrical devices of the building do not meet the current norms and rules, do not comply with the requirements of PUE and TKP454.04-149-2009 "Electrical systems of residential and public buildings."

Actual wear and tear is 80%.

It is necessary to carry out the design of power supply, electrical equipment and electrical lighting of the building on the basis of the customer's task, issued technical conditions, tasks of adjacent groups.

The project shall be executed in accordance with the current norms and regulations, the requirements of PUE and TKP454.04-149-2009 "Electrical equipment systems of residential and public buildings."

Complex output

On the basis of the above conclusions and recommendations based on the results of a technical survey of the building of special vehicles for multifunctional along Trolleybus Street, 10 in Gomel, by specialists of the ODO Zhilpromproekt, one can make a comprehensive conclusion that the wear and tear of a residential building (62.8%) and taking into account the requirements of the existing regulatory documents of fire and sanitary inspections and in accordance with TKP 45.1.042082010, Table 9.1, the building has category IV - inoperable (unsatisfactory) condition - urgent load limitation is necessary. Overhaul, reinforcement or replacement of elements or structures is required (specified by calculation). When redeveloping spaces and adding the second floor (as specified in the proposed redevelopment scheme), you need to:

strengthening existing foundations

partially strengthen, partially implement new external and internal walls;

in the floor level of the first floor, make a monolithic belt;

Implement the recommendations of the above sections.

This technical report is not a documentation for the performance of works. According to the given recommendations, design and estimate documentation should be developed.

All types of works on reinforcement and replacement of building structures shall be carried out by specialized organizations in accordance with the developed design solutions.

Drawings content

icon 0111 АВАБИ Троллейбусная 10.dwg

0111  АВАБИ Троллейбусная 10.dwg

icon План отдел1 письмо.dwg

План отдел1 письмо.dwg

icon Съемка АВАБИ Троллейбусная 10.dwg

Съемка АВАБИ Троллейбусная 10.dwg

icon Съемка для письма.dwg

Съемка для письма.dwg

icon Съемка ориг АВАБИ Троллейбусная 10.dwg

Съемка ориг АВАБИ Троллейбусная 10.dwg

icon Тролейбусная 10. Магазин.. для Игоря..dwg

Тролейбусная 10. Магазин.. для Игоря..dwg
up Up