Description

High-pressure heater PV-900-380-18-1 for turbine unit T-250/300-240 or K-250-240-2 TMZ. The HPH operates at steam parameters before entering the heater: pressure 1.69 MPa, temperature 435 С and steam flow rate 9.8 kg/s. Feedwater parameters at this: pressure 324 ata, temperature 170 С and flow rate 263.9 kg/s