Office overhaul. Complex of engineering and technical means of security in St. Petersburg
- Added: 09.07.2014
- Size: 2 MB
- Downloads: 0
Description
Project's Content
|
|
00_титул+общие данные.doc
|
02_ПЗ.doc
|
03-09_условные_план_recover.dwg
|
10_структура.dwg
|
11-_электрические схемы+.dwg
|
кабельный журнал.doc
|
Приложение 1+.docx
|
Расчет тока потребления.doc
|
Спецификация.doc
|
Additional information
Contents
Introduction
1 Composition and purpose of system-forming equipment
2 Composition and purpose of line equipment
3 Structural diagram and operating principle of the system
4 System functions
5 Arrangement of MCDS system equipment
6 Uninterruptible power supply system
7 Installation Instructions
8 Environmental protection
9 Occupational safety measures
10 Fire safety measures
1 introduction
Basis for project development.
The project is based on:
Architectural solutions
Engineering Specification
The following regulatory and technical documents were used in the development of the project:
• Federal Law N 123FZ "Technical Regulations on Fire Safety Requirements";
• RD 78.36.0032002 "Engineering and technical strengthening.. Security equipment. Requirements and design standards for the protection of facilities from criminal encroachments ";
• RD 78.36.00299 "" Technical means of facilities safety systems. Symbols of graphical elements of the system ";
• PUE (Edition 7, 2002) "Electrical Installation Rules."
In accordance with the developed working drawings, specifications for equipment and cable products have been compiled.
The access control and control system provides automated, regulated access to the office premises. The system is designed to organize authorized personnel passage, with the issuance of personal identification cards with the possibility of storing a database, recording events and recording working hours.
MCDS system generates and provides information about events occurring in the system in graphical and text form, through software on the system server. Additionally, in graphic and text form, information is provided to the Automated Workplace (AWS).
2 composition and purpose of system forming equipment
The system-forming equipment is Parsec brand equipment (Russia):
• PC-Interface NIA01USB, - PC interface, is used to connect the controller to the USB port of the computer;
• The CNC02IP.M Ethernet gateway allows you to combine geographically remote system segments over Ethernet
• The NITW module is used to interface NC Series network controllers with third-party readers;
• The UIM01 module is used to interface NC Series network controllers with turnstiles;
• EC01 module is used to organize complex algorithms for control of passage points
• NC2000DIP, NC-2000-IP, NC1000, NC-100K-IP, NC5000 Access Control Controllers are designed to control one access point by reading identification codes (contactless access cards), checking access rights and closing (opening) of relay contacts, control interfaces and RSLs;
• Parsec Server/Parsec AWS;
• Cisco Catalyst switch, 24 ports.
3 composition and purpose of line equipment
MCDS linear part equipment includes:
• IO1025 security magnetic contact detector is used to obtain information about the door condition (unauthorized opening and/or holding;
• electromagnetic lock Aleko AL15012/24, designed to lock doors of rooms entrance/exit;
• Door finisher, for doors weighing up to 100 kg DORMA TS72;
• readers PRG07, NR-A07, PREH08, PR-EH03, NREH03, NR-EH05, NREH09, NR-EH16 are designed to read identification card code with EM Marin standard (as well as active PRUD tags on G07)
• MA reader 120 is designed for reading, biometric data (fingerprint) and transmitting data to the MCDS controller;
• turnstiles of the companies Oma, Perco, Praktika and Rostov-Don;
• Nice and Come barriers;
• Aperio mechanical lock with electronic control and built-in reader of contactless identification cards, connected to the hub via radio channel;
• Goblin card receiver.
The complete composition of MCDS equipment with the quantity of consumables and auxiliary materials is given in the equipment specification.
4 structural diagram and operating principle of the system
Structural diagram of MCDS system is given in Figure 8.
The MCDS server (Server "ParsecNet") connected to the Ethernet network is used as the main receiving and control equipment of the access control system. The server constantly polls devices connected through the local Ethernet network, receives information about the status of door loops, requests for verification of access codes and issues commands according to the specified algorithm. To differentiate access to the entrance/exit to the premises near the door, proximity readers are installed to work with contactless Emmarine access cards, which are used as electronic pass tools. PREH08 reader is connected to AWS "ParsecNet" for on-line clearance processing.
Software Description:
The integrated ParsecNET 3 system supports one to several hundred pass points. The system uses the cards as the Proximity keys.
The PNSoft software supports, in addition to the standard, many additional functions necessary: a database of personnel photos, graphical plans of alarm zones, time recording, and so on.
ParsecNET 3 also allows you to export generated reports, personnel databases, etc. to CSV files (these are text files in which data is separated by certain characters, for example, semicolons) and XML. It is also possible to export reports to many formats (pdf, doc, xls and others).
The ParsecNET 3 software can run on a single PC or simultaneously on multiple LAN devices. In this case, the hardware can be connected simultaneously to several PCs. To access the server, you must use a license key, the server stores a general configuration and a list of available modules. The software installed on the server collects and stores information, as well as organizing network communication and data exchange. All system management and administration functions are available both from workstations (when you enter the System Administrator password) and from the server.
The maximum number of concurrent PCs in system ParsecNET 3 is determined when ordering the system. The project provides the software order for one AWS and one server.
The access control and monitoring system includes emergency exit buttons, which are required in critical situations (fire, emergency evacuation). These emergency exit buttons are connected to the MCDS system controller so that even if communication with the MCDS system server is lost, people can leave the room protected by the access system.
Software composition:
• Standard software version with the ability to support an unlimited number of pass points;
• additional workstation module for the system;
• Time and attendance module with report generator;
• Module for preparation, maintenance of database and printing of plastic cards;
• A module for automatically entering documents from the scanner and recognizing them in order to automate the processing of pass requests.
5 system functions
MCDS provides the following main functions:
• Setting the operating procedures of the system in accordance with the requirements of the administrator and the established modes;
• possibility of differentiating user rights using personal personal code;
• output of "alarm" signals to the duty station;
• provision of information to the duty station on the condition of each door of the premises;
• control of the door loop for short circuit, break, "norm" of the detector, "alarm" of the detector;
• acknowledgement of reception of "alarm" signal with corresponding indication on WS of the operational duty officer;
• maintenance, viewing and printing of operational information protocols;
• detection of unauthorized entry of people into the premises of the object, when the door is broken;
• prompt preparation and issuance of contactless cards-passes;
• accounting of employees "working hours;
• Automatic and manual control of access controllers;
• manual unlocking of the access point during emergency evacuation (from the WS of the operational duty officer).
6 arrangement of equipment of the scud system
MCDS system equipment is located taking into account the requirements of regulatory documents and ergonomics of use:
• CNC02IP.M network gateway and NIA01USB interface converter are installed on the wall;
• Access control controller (CD) NC2000IP, NC-1000, NC100KIP, NC-5000 are installed on the wall in the dam space in the protected rooms, according to the project plans;
• The NC2000DIP Access Control Controller (AP) is installed in a cabinet with DINrakes on the wall in the dam space in the protected rooms, according to the project plans;
• The "ParsecNet" server and Cisco Catalyst switch are installed in the Server Server (Note 20);
• AWS "ParsecNet" shall be installed in the Personnel Department (item 4);
• Turnstiles are installed in the Sales Hall (item 1);
• Barriers shall be installed at the places of entry to the surrounding area.
Refer to MCDS Equipment and Cable Route Layout Plans (Sheets 4-6) for more precise installation locations
7 UNINTERRUPTED POWER SUPPLY SYSTEM
The access control and monitoring system is a category 1 power consumer, and its uninterrupted power supply is provided from two independent power sources:
During normal operation from 220V, 50Hz power supply of the access control and monitoring system equipment is performed according to the power supply assignment, APPENDIX 1.
In case of loss of 220V, 50Hz network, the access system equipment goes into operation from the built-in battery 12V.
The storage battery capacity is designed to provide power to the specified devices of the access control system in standby mode - according to the Table of storage battery capacity calculation. Switching from the main power supply to the standby power supply is carried out automatically, without disrupting the operation of consumers.
Grounding of electrical equipment housings is performed by the third core of supply cables in accordance with the requirements of PUE, specifications of manufacturers and the grounding scheme existing on the site.
8 installation instructions
The RS485 interface lines are a symmetrical cable for the collection and transmission of 2x2x0.64 CAB data and are routed according to the layouts. The 485th interface lines shall be laid at a distance of not less than 500 mm from power lines 220V or other lines causing significant electromagnetic interference.
Cable routes to the announcer security magnetocontact cut-in and the EXIT buttons are carried out by the KPSVVngLS cable h2kh0.5.
The cable route to the readers is made by CQR 6x0.22 cable.
Cable routes shall be laid according to layouts along corridors in cable trays, in rooms in corrugated pipes with attachment to clips or cable ties.
Descents of a cable to readers and the EXIT buttons from a ceiling are carried out in cable channels 32х12.5.
Put the data and power cables in such a way as not to prevent the possibility of removing the switches/server equipment and performing routine/emergency work.
When performing electrical installation works, follow SNiP 3.05.0685, PUE (7th edition), GOST 12.1.00476 and fire safety rules during construction and installation works.
Individual tests shall be carried out at the incoming control stage. The tests shall include visual inspection and serviceability check of the equipment.
9 environmental protection
Due to the absence of harmful effects on the environment, special measures for environmental protection are not provided.
10 occupational safety measures
According to safety requirements, the set of technical means corresponds to:
• GOST 12.2.00374 "Production equipment. General safety requirements ";
• GOST 2586183 "Computer Equipment Safety Requirements."
Laying of a cable be on the ball to carry out according to "Interindustry rules on labor protection during the work at height" PM0122000 SWEAT.
All metal parts of electrical installations, electrical equipment housing, steel structures that may be energized due to insulation failure shall be grounded. The grounding bus of SH electrical equipment is used for grounding.
All equipment under AC voltage in relation to the enclosure exceeding 24V shall be protected against accidental contact and shall have protective grounding.
The transient resistance between the grounding clamp and the housing shall not exceed 0.05 ohms.
According to the method of protection against electric shock, technical means correspond to class II as per GOST 886593.
Installation and adjustment of equipment shall be carried out in accordance with the intersectoral rules on labor protection POT RM-01602001
The equipment shall be installed in such a way as to ensure its safe operation and maintenance.
Before admission to the work of newly engaged employees, it is necessary to conduct their training and training in accordance with GOST 12.0.004.
In accordance with the above documents, the design documentation provides for the necessary measures to ensure safety and normal sanitary working conditions both during construction and installation work and during the operation of linear structures.
11 fire safety measures
Installation and adjustment of technical tools for measurement, collection of processing and transmission of information should be carried out in accordance with fire safety rules for power plants RD 15334.0-03.30100 (VPB010295).
Also, when conducting fire prevention measures, it is necessary to be guided by Federal Law No. 123F3 "Technical Regulations on Fire Safety Requirements."
Cable products used for the organization must have certificates of compliance with the Gosstandart of the Russian Federation.
In case of fire, the controllers receive a signal centrally from the fire alarm system. Signal is supplied to Emergency contacts in MCDS controllers. When combining several controllers, an additional external stabilized power supply of 12 V. In places where turnstiles are installed, mechanical gates are opened to evacuate people from the building.
In addition, a special button is inserted into the power supply circuit of each lock for emergency unlocking of doors in case of fire.
The principle of connection to the fire alarm system is as follows: Emergency contacts on Parsec controllers are connected to the relay output of the fire system, which is closed in case of alarm. This closes the Emergency connector terminals of the Parsec controller and unlocks the door until the fire alarm contacts are closed.
In accordance with the current "Fire Regulations" (SNiP 2.01.0285 *), it is necessary to use when laying a cable in the premises with a shell of material that does not support combustion.
All places of cable passage through walls, partitions and ceilings shall be sealed to ensure fire resistance of at least 0.75 h. The sealing shall be carried out using only non-combustible materials and compositions.
Operation of the system shall be carried out by a specialized organization with the preparation of relevant documents in accordance with the requirements of the current "Intersectoral Rules for Labor Protection (Safety Rules) during the Operation of Electrical Installations" POT P M 0162001.
The solutions provided by this draft do not affect the degree of fire resistance of buildings. During construction and installation works and during operation of the designed structures it is necessary to comply with the fire safety rules of the Russian Federation (PPB 012003).
03-09_условные_план_recover.dwg
10_структура.dwg
11-_электрические схемы+.dwg