Subject: Outdoor water supply networks
Topic: Design of the water supply network of the settlement
List of drawings: General Plan, Situational Diagram, Pressure Tower, Pressure Tower Section, Piezometric Head Graph, Stepped Water Consumption Schedule, Detailing of 1 Water Supply Ring, Fire Hydrant Detailing, Pipe Specification, Nodes.
Introduction
1. Water supply network of the settlement 5
1.1 Selection of a water supply system and construction of a water supply network 5
1.2 Construction of the water supply network 5
1.3 Determination of the procedure for reporting the water supply network 6
1.4 Determination of design water flow 7
1.4.1 Water consumption for irrigation of green spaces and streets 9
1.4.2 Industrial water consumption in village 9
1.5 Preparation of the water supply network for hydraulic calculation 13
1.6 Selection of pipes 13
1.7 Determination of pipe diameter and weight loss 15
1.8 Hydraulic calculation and coordination of water supply and water supply network 16
1.9 Determination of the required effluents at the junction of the water supply 19
1.10 Determination of the height of the oil tower and the capacity of the tank 20
1.10.1 Description of the water tank and determination of its volume 22
Conclusion 24
Links 25
The course work includes water supply to the city of Taraz. The area of the city is 92.75 hectares. here water supply systems are designed to meet the domestic and economic needs of the consumer. A water meter is placed in the water to determine the total flow of water. The source of water supply is a ring water pipe with a diameter of 100-250 mm along the street.
The water consumption for urban water supply is 90.02 l /s. Number of cycles 4, number of nodes 9. The water consumption for washing along the streets of the city is 6.3 m3, the diameter of the nodes is 100 mm. The water consumption for irrigation of green spaces of the city is 29.4 m3, the diameter of the canals is 100-250 mm. The height of the single-pitched tower Nm = 20.09761 m.
When calculating the exchange rate project, we calculate the daily mode of operation of pumps supplying water to this city, calculating the water supply of one quarter, as well as the daily costs of landscaping and washing city streets.
When water supply to Taraz, the diameter of the pipes was selected in the range of 100-500 mm. Pipe material steel. During the project, losses in nodes, piezometric losses, free losses, height of the tower losses were determined.