4. WATER SUPPLY.
4.1 A drinking water supply system is designed in the building.
4.2 Cold and hot water supply pipelines are installed
from steel galvanized water and gas pipes
Pipelines with a diameter of more than 50 mm should be mounted on welding.
For the maintenance of fittings located above. 1.60m from level
Gender, use
mobile towers and stepladders, subject to compliance
fire safety rules.
4.3 Main networks of cold, hot water supply
insulated by thermal insulation
4.4 Laying of cold and hot water supply pipelines at the intersection of pe
Covers, interior walls and partitions should be provided in sleeves made of non-combustible materials with a gap between the sleeves and pipelines of 10-20 mm filled with a carefully compacted linen strand soaked in crumpled clay.
4.5 Wiring of B1, T3 systems in plumbing rooms to the equipment
The distance between the supports is made of PPRC polypropylene pipes. B1 systems of polypropylene pipelines accept for pipelines of T3 systems no more than 0.5m. Shut-off no more than 0.6m and pipelines polypropylene piping systems B1,T3
4.6 Polypropylene pipes and fittings must be certified
conformities and hygienic certificates.
4.7 Accounting for the amount of water consumed in the building's water supply system
is carried out from the designed water metering unit.