• RU
  • icon Waiting For Moderation: 2
Menu

Calculation of power supply of two-storey cottage, pos. Bezhin Lug

  • Added: 09.07.2014
  • Size: 216 KB
  • Downloads: 0
Find out how to download this material

Description

Calculation of electric load of 2-storey cottage (RPZ, drawing)

Project's Content

icon
icon РПЗ.doc
icon Чертёж.dwg

Additional information

Contents

WITH ABOUT D E P AND N AND E

1. Calculation of lighting load

2. Socket load calculation

3. Summary load of floor boards

4. Calculation of voltage losses

5. Calculation of transformer substation

Floor Plan I. Outlet network

Floor Plan II. Outlet network

Floor Plan I. Electric lighting

Floor Plan II. Electric lighting

Electrical equipment of the house. One-line schematic diagram

Electrical Specification

Literature

1. General part

This documentation considers the electrical part of a two-story country house at the address Moscow region. Dmitrov, st. 2nd Filevskaya, house

The documentation is developed at the project stage on the basis of the following initial data:

- architectural and construction drawings;

- technical assignment of the customer;

- requirements in force in the territory of the Russian Federation and regulatory documents:

SNiP 2.08.0289 "Public buildings and structures";

SNiP 2.08.0189 "Residential buildings ";

MGSN 3.0101 "Residential buildings";

MGSN4.1498 "Catering enterprises";

RD 34.20.18594 "Instructions for urban design

electrical networks "with additional calculation

electrical loads;

RD 34.21.12287 "Instructions for lightning protection of buildings and

structures ";

SNiP 3.05.0685 "Electrical devices";

VSN 5988 "Electrical equipment of residential and public

buildings. Design Standards ";

SNiP 2.01.0285 "Fire Regulations and Regulations";

SNiP 230595 "Natural and artificial lighting";

SNiP 210299 "Parking";

MGSN 5.0194 "Car parking";

SNiP 2.040984 "Fire automation of buildings and structures";

NPB "Fire Safety Standards";

MGSN 4.04.94 "Multifunctional buildings and complexes";

TCH

PUE-98 "Electrical Installation Devices Rules"

(Seventh Edition)

The scope of this project includes the calculation of the power of electrical loads and the adoption of basic technical decisions in the following sections :

- electrical equipment of the house;

- power electrical equipment and electric lighting of common house

premises of a two-story country house;

- lightning protection and protective measures of a two-story country house;

- energy-saving activities.

The documentation is made in accordance with the applicable norms and regulations in the territory of the Russian Federation.

External power supply networks are not included in the scope of this project. Some objects (such as outdoor lighting, facade lighting) connected to the BRU of a multi-storey residential building with the first non-residential floors are considered only in the calculation of loads.

Drawings content

icon Чертёж.dwg

Чертёж.dwg
up Up