Description

GENERAL PART

 

The project is developed in accordance with the Design Task.

The working project is designed for construction in the 1V climatic region with the calculation of the winter temperature of the outside air -35 * C

Snow cover weight 1.00 kPa.

Wind head speed 0.38 kPa

Responsibility Class I,  

degree of fire resistance II

 

ARCHITECTURAL AND PLANNING SOLUTION

 

The winter garden in the plan has an octagonal shape.

Overall dimensions 11,58х1,58m.

In the central part of the Winter Garden there is a recreation area marked with a podium.

The total height of the building h-5,850m

 

DESIGN SOLUTION

 

Foundations - Monolithic slab h=300 mm

Plinth - brickwork thickness b-250mm,  

Exterior walls - wooden frame with slatted panel cladding

Basement KORPo-1NF/100/2,0/50 GOST 530-2007 with insulation with thermal insulation boards on a basalt basis according to GOST 9573-96, r-50kg/m3, b-100mm.  

External walls - Wooden racks 50x150mm with insulation with heat-insulating boards on a basalt basis according to GOST 9573-96, r-50kg/m3, b-150mm.

Masonry should be carried out on cement-sand mortar M50 at an outside temperature not lower than  

-3 C, at temperatures from -3 to -20 C on cement-sand mortar M100 with the addition of  

plasticizers and antifreeze additives. External and internal walls reinforced with mesh

∅5VR I with 50x50mm cells through 5 rows of masonry.  Mesh weight 9,7kg/m3.

From the inside, the exterior walls are plastered with a cement-sand mortar M50 with a thickness of 15 mm (high-

quality plaster. Fasten the insulation  with fishunkers 5pcs. per 1m2.

The roof is asphalt shingles.

Gutter - external organized.

Stained glass windows - aluminum with thermal protection.

Interior decoration of the premises - porcelain stoneware, granite, wooden slatted panels.

Exterior finish - brush with marble chips

Floors - porcelain stoneware

Blind - concrete on crushed stone base h-50mm and sand h-100mm, width 500mm

 

FIRE PREVENTION MEASURES

 

Fire-fighting measures were carried out in full compliance with  the SNiP RK 2.02.01-2001 "Fire safety of buildings and structures"