Apartment building with built-in rooms, built-in garage - Automatic fire extinguishing

  • Added: 01.07.2014
  • Size: 1 MB
  • Downloads: 0
Find out how to download this material

Description

Automation of fire extinguishing of underground parking of an apartment building. Draft, explanatory note.

Project's Content

icon
icon
icon 00_Titul.doc
icon 01_OD.docx
icon 02_PZ.docx
icon 03_UO.docx
icon 04-08_Graf.dwg
icon 09_Tabl.docx
icon 10_KJ.docx
icon 11S_Spec.docx
icon Shtamp.dwg
icon xKrasnop.dwg

Additional information

Contents

1. Grounds for development of design documentation

2. Appointment

3. Brief description of the protected object

4. Design Input

5. Main design solutions and operating principle of the plant

6. Equipment Installation and Placement Solutions

7. Power supply

8. Grounding (busy)

9. Corrosion protection measures

10. Environmental protection measures

11. Professional and qualification composition of persons working at the facility for maintenance and operation of the system

12. Plant Maintenance and Maintenance

13. Health and safety measures

1. Grounds for development of design documentation.

This project is based on the contract for the design of the automatic fire alarm, fire extinguishing and warning and evacuation control system.

Design and estimate documentation is made in accordance with the current regulatory documents:

- Federal Law of the Russian Federation of July 22, 2008 N 123FZ "Technical Regulations on Fire Safety Requirements."

- GOST 21.10197 "Basic requirements for design and working documentation.

- SP 5.13130.2009 "Fire protection systems. Fire alarm and fire extinguishing units are automatic. Design Codes and Regulations. "

- SP 3.13130.2009 "Fire protection systems. Warning and management system for evacuation of people in case of fire. Fire safety requirements. "

- SP 12.13130.2009 "Determination of categories of rooms, buildings and outdoor installations by explosion and fire hazard."

- RD 78.VO.0199 "Technical means of security systems of objects. System Symbol Schematic Graphics.

- RD 78.14593 "Guidance document. Systems and complexes of security, fire and fire alarm. Rules for production and acceptance of works. "

- RTM.25.48882 "Automatic fire extinguishing plants and fire safety and fire alarm systems, standards of the number of personnel engaged in technical repair and maintenance."

- PUE "Electrical Installation Rules."

2. Purpose.

Automatic fire extinguishing system is designed for fire detection and localization and extinguishing of fire sources with output of appropriate signals to the security panel and activation of the fire warning system.

3. Brief description of the protected object.

The object to be protected by the automatic powder fire extinguishing plant is an underground parking lot of a 25-story residential building.

Site address: 196240, St. Petersburg, Krasnoputilovskaya St., d.113, corps.1, letter A.

The building is a single-section 25story residential building located on the site, with an area of ​ ​ apartments in one section on one floor less than 500 m ², with an underground closed parking lot, the first floor with commercial premises and 24 residential floors. The roof is insulated, combined. The height of the residential building (from the ground to the top of the sill of the upper residential floor) is 74.7 m. The height to the parapet of the highest point of the building from the ground is 86.0 m.

The total area of ​ ​ a residential building: 20532.2 m ².

The total area of ​ ​ the underground floor: 3525.1 m ².

The total area protected by the fire fighting plant: 3246 m ².

Structural fire hazard class of building C0.

Degree of fire resistance - I.

The building has primary fire extinguishing equipment that provides the possibility of fire elimination.

Security post, located in room 002 of the underground floor.

4. Design Input.

The following are used as initial information for design:

Technical Assignment for Development of Automatic Powder Fire Extinguishing Plant Design.

Room layouts and room finish list provided by Owner.

6. Solutions for installation and placement of equipment.

Installation is recommended in the following sequence:

Preparation works, laying and drawing of cables and wires into embedded units and pipes, wire laying, installation of detectors, installation and installation of fire station.

Preparatory works include:

- check of integrity and operability of devices and sensors;

- preparation of materials and workplaces .

Fire alarm loops and warning lines in protected rooms shall be laid separately from all power cables, lighting cables and wires. In case of parallel laying, the distance between fire alarm wires with power and lighting wires must be at least 0.5 m. If it is necessary to lay these wires at a distance of less than 0.5 m from power and lighting wires, they must have protection against aiming. It is allowed to reduce the distance to 0.25 m from IR wires without protection from aiming to single lighting cables and wires. When laying the wires of the fire alarm system, and the warning system along one route, it is allowed to position them close to each other.

Wiring routes should be selected as short as possible, taking into account the location of power, lighting, radio broadcasting networks, water and gas pipelines, as well as other switches.

In places where wires and cables pass through walls, slab or their exit outside, the gaps between wires, cables and pipe (conduit, opening) should be closed with easily removable mass from non-combustible material.

Attach wiring elements with clips or braces at inputs to instruments and boxes at a distance of 50100mm from them.

When laying cables at turning points at a rotation angle close to 90 degrees, the bending radius must be at least ten cable diameters. Only one turn with a bend radius of seven cable diameters is allowed.

When laying multiple wires in the same route, place them in the same pipe or cable channel.

Connections and branches of electrical wiring elements shall be made in boxes or inside electrical installations of articles by soldering or using screws (use of screw connections in places with high humidity is not allowed). Connections of fire alarm cables shall be made in fire-resistant mounting boxes KM-O. Conductor stock shall be provided at the wire connection points to allow re-connection. At points of connections and branches the wiring shall not experience mechanical forces. Connection and branch points shall be accessible for inspection and repair.

Placement of equipment shall prevent accidental drop or movement on the installation surface, at which damage to the connected wires is possible. When placing instruments it is necessary to ensure normal illumination of instrument panels.

Locations of equipment and cable gaskets on the drawings are indicated conditionally and specified during installation, changes are allowed within the limits specified below.

The devices shall be installed in the place defined by the project at a height convenient for maintenance (within 0.81.5m from the floor and not closer than 0.1m from the ceiling, at a distance of 1m from heating systems and not closer than 50mm from other equipment). To prevent unauthorized access, the project provides cabinets for the installation of devices.

Thermal fire detectors shall be installed on the ceiling in places defined by the design at a distance of not less than 0.1 m from the walls. In places where there is a risk of mechanical damage to the detector, provide a protective structure that does not disturb the operability of the detector. Detectors shall be installed not closer than 1m from plenum ventilation and not closer than 0.5m from lighting devices. Thermal fire detectors in rooms with ceiling height up to 3.5m shall be installed at a distance of not more than 2.5m from the wall and not more than 5.0m between them. Thermal fire detectors in rooms with ceiling height of 3.56.0m shall be installed at a distance of not more than 2.0m from the wall and not more than 4.5m between them. Since heat detectors are used to start the fire extinguishing system, the distance between the rows of detectors is halved.

Manual fire detectors "START OF POWDER," install on the wall, at a height of 1.5 m from the floor level in places determined by the design, at a distance from sources of strong electromagnetic radiation, at a distance of at least 0.75 m from other controls and objects that prevent free access to the detector. A sealed box 253x136x115 is provided for installing the detectors.

Audible annunciators shall be installed in places defined by the project on the wall at a height of not less than 2.3 m from the floor level and not less than 150 mm from the ceiling to the upper part.

"Automatic OFF," "Powder Leave," "Powder Do Not Enter" light annunciators shall be installed in the places specified by the project, above the evacuation exits (or on the side, in the immediate vicinity of the evacuation exits) at a height of not less than 2 m from the floor level and not closer than 0.1 m from the ceiling.

Powder fire extinguishing modules are mounted on the ceiling. Special fasteners offered by the manufacturer may be used to secure the modules. Installation locations are defined by the design and specified during installation, taking into account the location of cars and possible shading zones. The direction of powder discharge must coincide with the axis of symmetry of the protection area.

When installing the equipment, it is necessary to follow the certificates and technical documentation supplied by the manufacturers.

To prevent unauthorized pressing and false operation of fire extinguishing systems, it is necessary to seal hermoboxes and manual fire detectors.

8. Grounding (zeroing).

To ensure the safety of people, all electrical equipment of fire alarm units and fire extinguishing system must be reliably grounded (busy) in accordance with PUE requirements.

9. Corrosion protection measures.

Corrosion protection shall be provided for auxiliary steel structures for attachment of detectors, equipment and cables. Protection is performed by applying protective painting with enamels of PF115 grades GOST 646576 in two layers on a pre-cleaned and defatted surface. Coating color as per GOST 1420269 and GOST 12402676.

10. Environmental protection activities.

Due to the absence of harmful emissions, environmental protection measures are not provided.

11. Professional and qualification composition of persons working at the facility for maintenance and operation of the system.

The personnel number standards take into account the performance of maintenance, and scheduled maintenance of the fire extinguishing plant by the enterprise, the organization operating these plants.

Maintenance and ongoing repair of electrical installations are carried out by OPS electricians.

The results of the calculation of the number of personnel: OPS electrician - 1 person/shift.

The number of OPS electricians for maintenance and maintenance of fire extinguishing plants takes into account the necessary time for all components of the plant, including PS loops.

12. Maintenance and maintenance of the plant.

The main purpose of fire fighting maintenance is to maintain it in operable condition during its entire service life.

The maintenance and repair structure includes the following activities:

- maintenance;

- scheduled maintenance;

- planned overhaul;

- unscheduled repair.

Observation of planned work of installation, elimination of the found defects, adjustment, control, approbation and check belongs to maintenance.

The scope of maintenance includes partial disassembly, replacement or repair of wires and cable structures. Measurements and tests of equipment and elimination of detected defects are carried out.

The scope of overhaul, in addition to the work provided for by the current repair, includes the replacement of worn-out plant elements and improvement of equipment operational capabilities.

Unscheduled repairs are carried out in the scope of current or major repairs and are carried out after a fire, accident caused by unsatisfactory operation of the equipment, or to prevent it.

When performing maintenance works, the requirements of STP 0010102 "Operating and Maintenance Instructions" and RD 78.14593 of the Ministry of Internal Affairs of Russia "Rules for the performance and acceptance of works should be followed. Systems and complexes of security, fire and fire alarm. "