Aerodynamic calculation of ventilation system
- Added: 14.08.2014
- Size: 231 KB
- Downloads: 1
Description
2.Computed coolant parameters for heating systems 77-55 0С.
3. The system is filled with water from the designed water pipeline, through the UPO-1 connection and maintenance unit.
Project's Content
|
|
|
ГРАФИКА.dwg
|
Общие указания.doc
|
СО ОВ.doc
|
Additional information
Task
General Instructions
Heat supply source - gas boiler AOGV24OP "Alfa-Kalor."
Design parameters of coolant for heating systems 7755 0С.
The system is filled with water from the designed water pipeline, through the connection and maintenance unit of UPO1.
Air removal from the heating system is provided through air vents installed on heating devices.
Pipes for laying the heating system are three-layer metal plastic.
Access to instruments shall be Ø16 mm.
Heating system pipes are laid hidden, in bars.
To protect against mechanical damage, the heating system pipelines are additionally protected by a corrugated pipe.