• RU
  • icon Waiting For Moderation: 14
Menu

Public block. Cold supply. Automation diagram

  • Added: 03.07.2014
  • Size: 2 MB
  • Downloads: 0
Find out how to download this material

Description

Residential complex dispatch system: - explanatory note-graphic part-specification

Project's Content

icon
icon
icon plot.log
icon АК_01.dwg
icon АК_02_10.dwg
icon АК_11.dwg
icon АК_12.DWG
icon АК_13.dwg
icon АК_14_21.dwg
icon АК_22_23.dwg
icon АК_24.dwg
icon АК_25.dwg
icon АК_26_27.dwg
icon АК_28.dwg
icon АК_29.DWG
icon АК_ПЗ.doc
icon АК_С.dwg
icon АК_СО.doc
icon Титульный АК.dwg
icon ШтампАСДУ.dwg
icon ШтампУИСП.dwg

Additional information

1. Common part.

1.1. Project Section "System Automation System. Engineering Systems Dispatching "includes the following subsections:

• Automation and dispatching of engineering systems of the complex - ASDU IR;

• Control of engineering systems in case of fire - ULIC;

• Automatic fire fighting and fire water supply;

• Automation and dispatching of autonomous residential air conditioners.

1.2. Subsections of the project are developed on the basis of:

• contracts ____;

• approved "Private technical assignment for the development of the project on the automation and dispatching of engineering systems of a residential complex at the address: Moscow Region, Odincovskiy District, Novoivanovsky Village, Zarechye District";

• approved "Special Technical Conditions for Ensuring Fire Safety" of the residential complex developed by LLC "Fire Safety and Construction";

• architectural and planning decisions made;

• adopted technical solutions and technological tasks for system organization:

- general ventilation and air conditioning;

- heat supply;

- cold supply;

- water supply and sewerage;

- power supply and electrical lighting;

- smoke ventilation;

- fire alarm;

- sprinkler fire fighting and fire water supply;

- independent air conditioner systems (VRVs).

1.3. When developing the section, the requirements of the following regulatory documents are taken into account:

• SNiP 31012003 "Residential apartment buildings";

• SNiP 2.09.0487 "Administrative and household buildings";

• SNiP 2.08.0289 * "Public buildings and structures";

• SNiP 210299 * "Parking";

• SNiP 41012003 * "Heating, ventilation and air conditioning";

• SNiP 2.04.0185 * "Internal water supply and sewerage of buildings";

• SP 4110195 "Design of Thermal Points";

• SNiP 2.10197 "Fire safety of buildings and structures";

• NPB 8801 "Fire fighting and alarm systems. Design Codes and Regulations ";

• PUE "Electrical Installation Rules";

• SNiP 3.05.0685 "Electrical devices";

• SNiP 3.05.0785 "Automation Systems."

1.4. Characteristics of the object.

The residential complex includes:

• 6kt of detached residential buildings :

- building 1 - "Premiumclass" 8-9-storey 6-section;

- buildings 2,3,4,5 - "Businessesclass" 7-9-storey single-section;

- building 6 - "Business Class" 9-storey 5-section;

• 7-storey Public block attached to the end of building 1 (building 7);

• Two-storey underground parking lot for 886 cars, located under all buildings;

• Checkpoint at the main entrance to the compound;

• sewage pumping station (LPS) of stormwater;

• 2nd drain pump stations;

• Stormwater treatment facilities.

Residential buildings house apartments, lobby groups of residential sections, storerooms of residents, public premises, partially on the top floor there are technical rooms.

The public block provides for the accommodation of HOA premises and operation services, as well as FOK premises - sports halls, a pool with auxiliary rooms, circle, SPA premises, a cafe for 50 seats.

2. Engineering systems to be automated and dispatched.

The section of ASDU IR design covers the following equipment of the facility engineering systems:

• general ventilation system (equipment of each structural part of the designed object is assigned an index: for housings 1... 6 -, indexes "1" "... 6" respectively; for the public block - index "O," for parking - index "A"; for CAT, the index was not assigned) as part of:

- air conditioning systems with air heating and air cooling OK3... OK6; O-K8 ;

- air conditioning system with air heating, air cooling and individual OK7 heater;

- incoming systems of parkings with airheating of AP1,P1"... AP14, P14";

- plenum systems with air heating P1, P2; AP15... AP18, 1-P1...1-P7, 1P10, 1-P11; OP1, O-P2; 5P1; 6-P1... 6-P6;

- supply systems with electric air heating 18, 1-P9;

- pritochnovytyazhny recirculation APR1AV30, A-PR2-A-V31 systems;

- plenum systems of apartments;

- exhaust systems B1... B4; AB1... AB29, A-B32... A-B45; OV3... O14, O-B18... O-B22; 1B1 … 1B25; 2-B1; 3 in 1; 4-B1; 5B1, A-B2; 6B1 … 6B13;

• installations of water air and thermal veils AU1...AU4, 1-U1...1-U3, 6U1;

• Domestic drinking water supply system consisting of:

- Hydro MPCEF, 3CR 157 pressurization unit with MPC control cabinet - 2 lips;

• household sewerage system consisting of:

- rainfall funnels with heating of 75 pcs.;

- drain pipelines - 30 pcs.;

- installation of faecal effluent transfer Multilift MD24.3.2 with LCD control system 109 - 10 pcs.;

- drain pumps KP 350M1 (1 slave) "Grundfos" and LC 1WC type control unit in technical sub-units - 20 pc.;

- drain pumps AP12.50.11.3 (1rab., 1res.) "Grundfos" and control unit of LCD108.400 type in emergency pits on -2 floor in car parks - 8 complete;

- drain pumps AP12.40.08.3 (1rab., 1res.) "Grundfos" and control unit of LCD108.400 type in VPT, ITP1, ITP-2 stations, in the pits of entrance ramps - 5 complex;

- drain pumps AP12.50.11.3 (1rab.) "Grundfos" and control unit of LCD108.400 type in plenum ventilation chambers for -2 parking lots - 10 sets;

- drain pumps AP12.40.08.3 (1rab.) "Grundfos" and control unit of LCD108.400 type in plenum ventilation chambers for -1 parking lots - 14 sets;

• Storm Water Sewage Pump Station;

• Storm water treatment facilities - 1 station;

• drainage pump stations - 2 pcs.;

• gas content control system of car parks;

• heat supply system in the volume of individual heat points (ITP1, ITP-2);

• cold supply system of the Public Unit consisting of:

- air-cooled refrigerating machine (YCSEB 040SB of company "YORK") - 2 pcs.;

- air cooler (GFH 067B/2x3N (D) F6/2P) of "YORK" company) - 2 pcs.;

- REG circulation pumps - 3 pcs.;

- coolant circulation pumps - 3 pcs.;

- system filling pump - 1 pc.;

- heat exchanger - 1 pc.;

- two-way valve with analog electric drive - 2 pcs.;

- gate with electric drive - 6 pcs.;

- expansion tank for water - 1 pc.;

- membrane tanks for ethylene glycol - 2 pcs.;

• power supply and electric lighting systems consisting of:

- switchgears and switchboards: parking - VRUA No. 1... VRUA No. 3; housing 1- 1VRU-1... 1-VRU-4; public block - VRUOB; building 2 is 2VRU; building 3 is 3VRU; building 4 is 4VRU; building 5 is 5VRU; housing 6 - 6VRU1 ... 6VRU3;

- switchboard of RCCAT;

- external lighting boards of the DBW.

The project section of ULSI covers the following equipment of the facility's engineering systems:

• smoke ventilation system of car parks consisting of:

- the systems of smoke removal from 1 compartment of parking at-2 level - A-VD1, AVD2;

- a system a subtime of 1 compartment to platforms locks of staircases 1.2 - A-PD1;

- Compartment 1 overpressure system in staircase tambour 3 - A-PD2;

- compartment 1 overpressure system in staircase tambour 4 and elevator 4- A-PD4 airlock;

- the systems of compensation inflow of 1 compartment on-2 level - A-PD5, APD6;

- pressure system of compartment 1 to staircases-locks of staircases 5.6 and elevators 5.6 to -1, -2 level - A-PD18;

- the systems of smoke removal from the 2nd compartment of parking at-1,-2 levels - A-VD3, AVD4 ;

- pressure system of compartment 2 to air locks of rooms at -2 level - A-PD7;

- compartment 2 pressure system to staircase tambours 1 and elevator 1 - A-PD8;

- pressure system of compartment 2 in the air-lock staircase 1 - A-PD9;

- compartment 2 pressure system to staircase tambours 2 and elevator 2 - A-PD10;

- a system a subtime 2 compartments to platforms locks of a staircase 3 and elevator 3 - A-PD11;

- compartment 2 overpressure system in staircase tambour 4 - A-PD12;

- compartment 2 pressure system to staircase locks 5 and elevator 5 at -2 level - A-PD13;

- the systems of compensation inflow 2 compartments on-2 level - A-PD14, APD15;

- pressure system of compartment 2 to the air lock of the water metering unit - A-PD21;

- the system of smoke removal from an entrance compartment on-2 level - A-VD5 ;

- the system of smoke removal from a sink compartment - A-VD6;

- the systems of smoke removal from the 3rd compartment of parking at-1,-2 levels - A-VD7, AVD8 ;

- compartment 3 pressure system to elevator 4 tambour lock at -2 level - A-PD16;

- compartment 3 pressure system to staircases tambours-locks 4.5 A-PD17;

- system a subtime 3 compartments to platforms locks of staircases 6,7 A-PD19;

- compartment 3 pressure system to staircase locks 7 and elevator 7 - A-PD20;

- the systems of compensation inflow 3 compartments on-1,-2 levels - A-PD22, APD23;

- the systems of smoke removal from the 4th compartment of parking at-2 level - A-VD9, AVD10 ;

- pressure system of compartment 4 to the vestibules-locks of the pump room and VRUA No. 2 A-PD24;

- a system a subtime 4 compartments to the platform lock of elevator 8 - A-PD25;

- a system a subtime 4 compartments to the platform lock of elevator 9 - A-PD26;

- pressure system of compartment 4 to the air lock of the pressure chamber - A-PD27;

- the systems of compensation inflow 4 compartments on-2 level - A-PD28, APD29;

- the systems of smoke removal from the 5th compartment of parking at-2 level - A-VD11, AVD12 ;

- a system a subtime of the 5th compartment to platforms locks of a staircase 11 and elevator 10 - A-PD30;

- compensation inflow system of compartment 5 to -2 level - A-PD32;

- the systems of smoke removal from the 6th compartment of parking at-1,-2 level - A-VD13, AVD14;

- pressure system of compartment 6 to staircase locks 11 and elevator 11 - A-PD34;

- pressure system of compartment 6 to staircase locks 12 and elevator 12 - A-PD35;

- pressure system of compartment 6 to staircase locks 13 and elevator 13 - A-PD36;

- a system a subtime of the 6th compartment to the platform lock VRU-A№3 - A-PD37;

- Compartment 6 overpressure system in staircase tambour 14 - A-PD37;

- the systems of compensation inflow of the 6th compartment on-1,-2 levels - A-PD38, APD39;

- the systems of smoke removal from the 7th compartment of parking at-2 level - A-VD15, AVD16 ;

- a system a subtime of the 7th compartment to platforms locks of staircases 11.12 - A-PD40;

- pressure system of compartment 7 in the air-lock staircase 13 - A-PD41;

- pressure system of compartment 7 in the air-lock staircase 14 and air-lock of elevator 14 A-PD42;

- a system a subtime of the 7th compartment to boiled and smoked platforms locks in axes B/71,B/72 - A-PD43;

- a system an entrance subtime on-1 level 6 of a compartment - A-PD44;

- the systems of compensation inflow of the 7th compartment on-2 level - A-PD45, APD46;

- the systems of smoke removal from the 8th compartment of parking at-1,-2 level - A-VD17, AVD18;

- compartment 8 pressure system to staircases tambours-locks 14.15 - A-PD47;

- pressure system of compartment 8 in the air-lock staircase 15 and air-lock of elevator 15 A-PD48;

- pressure system of compartment 8 in the air-lock staircase 16 and air-lock of elevator 16 A-PD49;

- pressure system of compartment 8 in the air-lock staircase 16 - A-PD50;

- pressure system of compartment 8 to the air locks of the staircase ITP2 A-PD51;

- the systems of compensation inflow of the 8th compartment on-1,-2 levels - A-PD52, APD53;

• smoke ventilation system of the 1 housing consisting of:

ladder and elevator unit along axis 5-3:

- the system of smoke removal from a corridor in axes 3-6 - 1VD1;

- the system of smoke removal from a corridor in axes 6-9 - 1VD2;

- the system of smoke removal from storerooms of 1 floor in axes 6-5 - 1VD3;

- overpressure system to the fire elevator shaft - 1-PD1;

- pressure system to the stairwell - 1-PD2;

- system of overpressure in the tambour-locks of storerooms of the 1st floor - 1-PD3; staircase unit along the axis 11-10:

- the system of smoke removal from a corridor in axes 911 - 1VD4;

- the system of smoke removal from storerooms of 1 floor in axes 1211 - 1-VD5;

- overpressure system to the fire elevator shaft - 1-PD4;

- system of overpressure in tambour locks of storerooms of the 1st floor - 1-PD5;

ladder and elevator unit along axis 14-13:

- the system of smoke removal from a corridor in axes 1314 - 1VD6;

- the system of smoke removal from storerooms of 1 floor in axes 1215 - 1VD7;

- overpressure system to the fire elevator shaft - 1-PD5;

- pressure system to the stairwell - 1-PD7;

- system of overpressure in tambour locks of storerooms of the 1st floor - 1-PD8;

ladder and elevator unit along axis 17-16:

- the system of smoke removal from a corridor in axes 1617 - 1VD8;

- the system of smoke removal from storerooms of 1 floor in axes 1518 - 1VD9;

- overpressure system to the fire elevator shaft - 1-PD5;

- pressure system to the stairwell - 1-PD10;

- system of overpressure in tambour locks of storerooms of the 1st floor - 1-PD11;

ladder and elevator unit along axis 20-19:

- the system of smoke removal from a corridor in axes 1920 - 1VD10;

- the system of smoke removal from storerooms of 1 floor in axes 1821 - 1VD11;

- overpressure system to the fire elevator shaft - 1-PD12;

- pressure system to the stairwell - 1-PD13;

- system of overpressure in tambour locks of storerooms of the 1st floor - 1-PD14;

ladder and elevator unit along axis 23-22:

- the system of smoke removal from a corridor in axes 2223 - 1-VD12;

- the system of smoke removal from storerooms of 1 floor in axes 2124 - 1VD13;

- overpressure system to the fire elevator shaft - 1-PD15;

- pressure system to the stairwell - 1-PD16;

- system of overpressure in tambour locks of storerooms of the 1st floor - 1-PD17;

staircase and elevator unit along axis 26-25

- the system of smoke removal from a corridor in axes 2526 - 1VD14;

- the system of smoke removal from storerooms of 1 floor in axes 12427 - 1-VD15;

- overpressure system to the fire elevator shaft - 1-PD18;

- pressure system to the stairwell - 1-PD19;

- system of overpressure in tambour locks of storerooms of the 1st floor - 1-PD20;

• smoke ventilation system of the Public Unit consisting of:

- smoke removal system from the corridor at elev. - 7.600 in axes 29127/GD1 - OVD1;

- smoke removal system from the corridor in axes 29127/DG1 (1.1... 3 floors) - DGD2;

- smoke removal systems from the HOA Management Room - HIA 3;

- overpressure system to elevator air lock - O-PD1;

- overpressure system to elevator shaft - O-PD2;

• smoke ventilation system of the 2 enclosures consisting of:

- the system of smoke removal from a corridor in axes 3739 - 2VD1;

- pressure system to the fire elevator shaft - 2-PD1;

- pressure system to the stairwell - 2-PD2;

• smoke ventilation system of 3 enclosures consisting of:

- the system of smoke removal from a corridor in axes 4345 - 3VD1;

- fire elevator shaft pressure system - 3-PD1;

- pressure system to the stairwell - 3-PD2;

• smoke ventilation system of 4 enclosures consisting of:

- the system of smoke removal from a corridor in axes 3739 - 4VD1;

- fire elevator shaft pressure system - 4-PD1;

- pressure system to the stairwell - 4-PD2;

• 5 housing smoke ventilation system consisting of:

- the system of smoke removal from a corridor in axes 5557 - 5VD1;

- smoke removal system from the pantries of the 1st floor - 5HD2;

- overpressure system to the fire elevator shaft - 5-PD1;

- pressure system to the stairwell - 5-PD2;

- system of overpressure in tambour locks of storerooms of the 1st floor - 5-PD3;

• smoke ventilation system 6 of the housing consisting of:

ladder and elevator unit along axis 62:

- the system of smoke removal from a corridor in axes 611621 - 6VD1;

- the system of smoke removal from storerooms of 1 floor in axes 6064 - 6-VD2;

- overpressure system to the fire elevator shaft - 6-PD1;

- pressure system to the stairwell - 6-PD2;

- system of overpressure in tambour locks of storerooms of the 1st floor - 6-PD3;

ladder and elevator unit along axis 66:

- the system of smoke removal from a corridor in axes 651661 - 6VD3;

- the system of smoke removal from storerooms of 1 floor in axes 6468 - 6-VD4;

- overpressure system to the fire elevator shaft - 6-PD4;

- pressure system to the stairwell - 6-PD5;

- system of overpressure in tambour locks of storerooms of the 1st floor - 6-PD6;

ladder and elevator unit along axis 70:

- the system of smoke removal from a corridor in axes 691701 - 6VD5;

- smoke removal system from storerooms of the 1st floor in axes 6872- 6-VD8;

- overpressure system to the fire elevator shaft - 6-PD7;

- pressure system to the stairwell - 6-PD8;

- system of overpressure in tambour locks of storerooms of the 1st floor - 6-PD9;

ladder and elevator unit along axis 74:

- the system of smoke removal from a corridor in axes 731741 - 6VD7;

- smoke removal system from storerooms of the 1st floor in axes 6872- 6-VD8;

- overpressure system to the fire elevator shaft - 6-PD10;

- pressure system to the stairwell - 6-PD11;

- system of overpressure in tambour locks of storerooms of the 1st floor - 6-PD12;

staircase and elevator unit along axis 78:

- the system of smoke removal from a corridor in axes 771781 - 6VD9;

- smoke removal system from storerooms of the 1st floor in axes 7277- 6-VD10;

- overpressure system to the fire elevator shaft - 6-PD13;

- pressure system to the stairwell - 6-PD14;

- system of overpressure in tambour locks of storerooms of the 1st floor - 6-PD15;

• devices for disconnection of fire-retarding valves of general ventilation in case of fire;

• devices for disconnection of general ventilation in case of fire;

• devices of elevators switching to "Fire hazard" mode;

• gate valves at water metering unit - 2 pcs.

The sprinkler water fire extinguishing and fire water supply system of the building covers the following equipment:

- car park sprinkler fire extinguishing station;

- fire-fighting water supply station of the parking lot;

- sprinkler fire extinguishing station, combined with fire water supply, for storerooms;

- distribution networks with the installation of fire cranes, sprinklers and deluge curtains.

The system of autonomous air conditioners at this stage covers the external units of the RXYQ series:

• external housing units 1 - 45 pcs in total;

• external housing units 2 - 14 pcs in total;

• external units of housing 3 - only 18 pcs.;

• external housing units 4 - only 18 pcs.;

• external housing units 5 - 18 pcs in total;

• external units of housing 6 - total 85 pcs.

Drawings content

icon АК_01.dwg

АК_01.dwg

icon АК_02_10.dwg

АК_02_10.dwg

icon АК_11.dwg

АК_11.dwg

icon АК_12.DWG

АК_12.DWG

icon АК_13.dwg

АК_13.dwg

icon АК_14_21.dwg

АК_14_21.dwg

icon АК_22_23.dwg

АК_22_23.dwg

icon АК_24.dwg

АК_24.dwg

icon АК_25.dwg

АК_25.dwg

icon АК_26_27.dwg

АК_26_27.dwg

icon АК_28.dwg

АК_28.dwg

icon АК_29.DWG

АК_29.DWG

icon АК_С.dwg

АК_С.dwg

icon Титульный АК.dwg

Титульный АК.dwg

icon ШтампУИСП.dwg

ШтампУИСП.dwg
up Up